According to Wu, the official associated account Base Build released an incident report stating that the Base mainnet experienced a network interruption on August 5, with block production paused for approximately 33 minutes. The incident was caused by the current sequencer being delayed due to on-chain activity, leading the Conductor to automatically switch to a new sequencer. However, this node was still in the deployment process and was unable to produce blocks, and the Conductor module was not enabled, preventing the triggering of the next switch. The team discovered the issue at 6:09 and officially initiated a response at 6:12 by manually pausing the automatic transfer and taking over as a healthy sequencer, ultimately resuming block production at 6:40. Base stated that it will optimize the sequencer cluster configuration and testing coverage to prevent similar incidents from occurring again.
吴说区块链
吴说区块链5.8. klo 14.46
According to Wu, BaseScan data shows that the Base network is experiencing anomalies, with the latest block height remaining at 33,792,704, and no new blocks have been produced for the past 19 minutes. Oklink also indicates that the Base network is experiencing issues. The status page of the Base public chain mainnet shows that the Base mainnet is currently experiencing anomalies, with the blockchain halting block production, affecting deposits, withdrawals, block generation, and lightning block processing. The official team is conducting an urgent investigation.